A job site refueling map is a one-page site plan that shows where fuel is delivered or dispensed, how the delivery truck reaches that spot, and what has to stay clear of it: buildings, storm drains, property lines, traffic and ignition sources. Build it before the first delivery, review it whenever the site layout changes, and hand it to every driver and fueling crew. It is the simplest way to keep equipment running without sending crews to retail stations, and it is the document an inspector or permit reviewer asks for first.

We deliver diesel, gasoline and DEF to job sites, equipment yards, generators and events, so we see the same failure repeatedly: the fuel is ordered, but nobody has decided where the truck goes. This guide covers what the map must show, how to draw it and how to keep it accurate as the site changes.

Anytimefuelpros
Keep Job Site Fueling on Track
Anytime Fuel Pros delivers diesel, gasoline, and DEF to job sites, equipment yards, and remote locations across Texas, Utah, and nationwide.

TL;DR

  • A refueling map marks the fuel point, the truck route in and out, the offload area, spill-response gear, storm drains and the distances to buildings and property lines.
  • Public guidance gives concrete checks: a proposed NFPA 30A revision calls for 10 feet from buildings and property lines, and EPA guidance says to mark refueling stations, storm drains and spill kits.
  • Build it in five steps: base plan, fuel points, routes, hazards and response gear, then a delivery window for each location.
  • Update it whenever grading, fencing, gates or laydown areas move, and give drivers the current version.
  • Multi-site operators get the most from one map format used at every site, with one fuel vendor supplying all of them.

Table of Contents

What a job site refueling map is for

The word “map” misleads some people. You do not need a GIS specialist or a special application. You need a scaled or clearly labeled site plan that answers four questions for anyone arriving with a fuel truck:

  1. Where do I enter, and which gate is mine?
  2. Where do I park and fuel?
  3. What is nearby that I must avoid or protect?
  4. Who do I call, and where is the spill kit?

Without those answers, drivers improvise. They park where equipment is working, block a haul road, or fuel next to a storm drain. Crews then stop work to move machines, which costs more than the delivery itself. A map removes the guesswork, shortens each stop and gives your safety lead something concrete to audit.

The same plan serves different operations in slightly different ways:

  • Construction and excavation: the fuel point shifts as earthwork progresses, so the map is revised often.
  • Mining and quarries: haul roads and remote pits make route clarity the main point.
  • Data centers and critical facilities: the map shows generator fill ports, tank locations and the approach for emergency refills.
  • Events and film production: fuel points for generators sit near crowds, so access lanes and separation from public areas lead the plan.
  • Municipal and fleet yards: the map documents where wet hosing happens and how it stays clear of drains.

What the map must show

There is no single national template for a refueling map, so the practical standard comes from the rules that apply to mobile fueling and spill prevention. Two public documents are useful models. A proposed NFPA 30A revision says site plans should show mobile fueling locations, storm drains, property lines, buildings and building openings. NFPA 30A is the fire code for motor fuel dispensing facilities. And one city’s permit guide for mobile fueling requires a site plan and a written safety and emergency response plan, including hose, spill-containment and emergency-contact information.

Turn those into a legend your crews can read at a glance:

Map element What to mark Why it matters
Fuel point The exact spot where the truck parks and fuels, with a number or name Drivers and crews agree on one location
Entry and exit route Gate, haul road, turning area, one-way flow Keeps the truck out of working zones
Offload or dispensing area Tank, generator fill port or equipment staging spot Shortens hose runs and stops
Buildings and openings Offices, trailers, doors, air intakes Sets separation distance
Property lines and fencing Boundaries and gates Sets separation distance
Storm drains and waterways Inlets, ditches, wetlands, swales Shows where a spill would travel
Spill kit and containment Kit location, berms, drip pans Makes the first response fast
Fire extinguisher Location and type Required access in an emergency
Contacts Site lead, fuel vendor dispatch, emergency numbers Removes delay when something goes wrong

Hazards and distances to put on the plan

This is where the map earns its keep. Each item below comes from a public source, so you can show an inspector where the number came from.

Separation from buildings and property lines. The proposed NFPA 30A language says mobile fueling must be at least 10 feet from property lines and buildings, and the fueling vehicle needs a 40-B:C extinguisher. That is a proposal, and local fire officials adopt their own rules, so confirm the distance your authority applies and draw it as a clear zone around the fuel point.

Extinguisher placement. OSHA’s 2000 letter of interpretation on a 1,000 gallon diesel tank says a fire extinguisher must sit 25 to 75 feet from an outdoor flammable-liquid storage area. Mark the extinguisher on the map inside that band, not wherever there is a free hook.

Collision protection. The same OSHA interpretation notes that dispensing units must be protected from collision damage, and that the measure depends on the risk. Where vehicles only approach to refuel, a curb or warning device can suffice. On the map, that means showing bollards, barriers or curbs next to the dispensing point and keeping haul traffic routed away from it.

Drains, waterways and spill response. EPA guidance says construction staff should identify refueling stations, storm-drain locations and waterways, and that spill plans should identify spill-kit locations. The Maple Grove permit guide asks for storm-drain openings, waterways or wetlands, drainage and spill containment on the plan. EPA’s same guidance describes good housekeeping as the cheapest and most cost-effective way to control a spill, with cleanup potentially costly. A fuel point placed uphill from a drain is a risk the map lets you see before it happens.

If you work with temporary tanks, check the tank rules before you pick the location. Our guide to temporary fuel tank regulations walks through what facility managers need to know, and our OSHA fuel handling requirements page covers the fueling rules for job sites and fleets.

Hazards and distances to put on the plan

How to build the map in five steps

Start with what you already have: a site logistics plan, an civil drawing or even an aerial screenshot. Software helps on large sites, and guides on construction site utilization planning recommend a version-controlled base map with layers for fencing, travel paths, utilities and egress. On a small site, a marked-up drawing does the same job.

Step 1: Fix the base plan

Show the boundary, fences, gates, buildings, trailers and permanent structures. Add north and a rough scale. Date the sheet and give it a version number. The common mistake here is using a design drawing that no longer matches the ground. Walk the site and correct it.

Step 2: Place each fuel point

Choose locations by what is fueled, not by convenience. Group heavy equipment where the work is, put generators at their own fill points and keep a separate stop for fleet vehicles. Check each point against the distances above. Then label it, such as “FP-1 north yard, diesel.”

Where the same fuel point serves both on-road and off-road equipment, note which fuel goes where. We deliver both clear diesel and dyed (red) diesel, and the label keeps the wrong fuel out of the wrong tank.

Step 3: Draw the route

Trace the truck’s path from the public road to the fuel point and back out, using one-way flow where possible. Check turning radius, ground conditions after rain, overhead lines and the places where pedestrians cross. Assign each delivery a gate, a route and an offload area, as site logistics guidance suggests. Routes that cross active work zones are the ones that cause delays.

Step 4: Add hazards and response gear

Mark storm drains, ditches and waterways, then the spill kit, containment, extinguisher and the emergency assembly point. Write the site contact and the fuel vendor’s dispatch number on the sheet itself, since a phone number buried in an email does not help at 5 a.m.

Step 5: Attach a delivery window

A map answers where. A schedule answers when. Give each fuel point a window that avoids shift changes, concrete pours, crane lifts and other peak traffic, and keep a name beside it for who meets the driver. This is the step that turns a drawing into an operating routine. Our construction site fueling workflow guide shows how to build that routine around deliveries.

Keep the map current

A refueling map is accurate on the day you make it and wrong a few weeks later. Earthwork changes grades, fences move, laydown areas expand and a gate closes. Site utilization guidance recommends updating plans continuously as conditions change, including as earthwork progresses.

A workable routine:

  • Name one owner. The superintendent or safety lead issues each revision, and nobody else edits it.
  • Set triggers. Any change to gates, haul roads, fuel points, drains or fencing means a new version.
  • Version and date every sheet. Drivers should be able to see at a glance which one is current.
  • Post it where people look. Put it at the gate, in the site office and with the fuel vendor.
  • Collect field changes. Let foremen flag changes from their phones so the map does not wait for the weekly meeting.

The benefits of a live map extend beyond fueling. A single, shared site picture helps coordinate vehicle movements and ease congestion, which is exactly what a morning with four deliveries and two concrete trucks needs.

Maps for multi-site and emergency operations

If you run several sites or several states, the map becomes a standard rather than a one-off. Use the same legend, the same sheet layout and the same checklist at every location, so a driver or a new superintendent finds each item in the same place. Pair that with a single fuel vendor and you remove the problem of explaining each site’s rules to a different supplier.

For emergencies, prepare the map ahead of time. When a storm or outage hits a data center or a municipal facility, the first delivery should not begin with a conversation about where the generator fill port is. Add a photo of each fill point, the access code or key holder, and an alternate route if the primary approach is blocked. Our generator fueling schedules guide explains how to plan refills for standby units.

For remote sites such as quarries, pits and oil and gas locations, add GPS coordinates or a pin to the sheet and note the last stretch of road that needs a high-clearance truck. The map then works for a driver who has never been there.

Maps for multi-site and emergency operations

Where we fit

We deliver on-site diesel (dyed and clear), gasoline and DEF, plus bulk fuel, fuel tank rentals and generator fueling, to job sites, equipment yards, data centers, mining operations and events. Our primary markets are San Antonio, Austin, Dallas-Fort Worth and Salt Lake City, and our national partner network extends service across the continental United States, with a single point of contact for multi-site needs.

Your map is what we work from: send us the fuel point, the gate and the delivery window, and our dispatch coordinates the rest. We run 24/7 service, aim for a 3-hour emergency response in covered areas, and send itemized invoices so each delivery ties back to a location on your map.

Anytimefuelpros

If you want a fueling plan built around your site, see our fuel delivery services, read how an on-site diesel delivery setup works, or place an order. For larger sites, our bulk fuel delivery and storage page covers tanks and tank fills.

FAQ

What is a fuel map?

On a job site, a fuel map is a plan that shows where fuel is stored, delivered and dispensed, and the route and hazards around each point. It lets drivers and crews find the right location quickly. It also gives safety staff a document to review against fire and spill rules.

Do I need special software to make a job site refueling map?

No. A marked-up site drawing with a legend, a version number and a date works on most sites. GIS tools help on large or fast-changing sites because they hold layers and update shared copies, but the content matters more than the tool.

How often should the map be updated?

Update it whenever a gate, haul road, fuel point, drain or fence changes, and review it on a set schedule even if nothing seems to have changed. On earthwork sites that can mean weekly. Always give drivers the latest version before the next delivery.

Who should receive the map?

The site superintendent, the safety lead, every foreman who fuels equipment and your fuel vendor’s dispatch. Post a copy at the gate and in the site office so that a driver arriving at night can find it.

Sources